Home / News / Why a Booster Pump Keeps Starting and Stopping: Check the Pressure Tank, Check Valve and Pipework First

Why a Booster Pump Keeps Starting and Stopping: Check the Pressure Tank, Check Valve and Pipework First

Published:2026-11-25 02:18 · 6 views

If a booster pump starts and stops very frequently, the pump itself is often not the first suspect. A pressure tank that has lost its charge stores too little pressurised water, so even a small draw-off drops the pressure and restarts the pump. A check valve that no longer seals lets water flow back after shutdown, causing the pump to restart even when no tap is open. Small hidden losses — a toilet fill valve, a dripping joint or a leaking fitting — have the same effect. Observe whether the pump cycles with all outlets closed, note the interval between starts, and check visible fittings first. Only when the tank, check valve and pipework are cleared should the pressure switch, controller or pump itself be suspected. Adjustment, wiring and any work on pressurised parts must be left to qualified personnel. You can compare booster ranges on our Pentax product pages, or send us the model, age and cycling pattern and we will help you judge the likely cause.